Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
N Z Med J ; 135(1559): 53-58, 2022 08 05.
Article in English | MEDLINE | ID: covidwho-2147482

ABSTRACT

AIM: To compare detection of SARS-CoV-2 from paired nasopharyngeal swabs (NPS) and saliva using molecular methods in common use for testing swabs in New Zealand. METHOD: Samples from individuals testing positive for SARS-CoV-2 in Auckland, Wellington and Dunedin were tested at the local laboratories using methods previously established for these sample types. RESULTS: One hundred and ninety-six paired samples from unique individuals were tested, with 46 (23%) positive from either sample type, of which 43/46 (93%) tested positive from NPS, and 42/46 (91%) from saliva, indicating no significant difference in performance between sample types (p=0.69). The average Δ Ct between saliva and nasopharyngeal swabs overall across the sample set was 0.22 cycles, indicating excellent concordance; however, the difference between NPS and saliva collected from the same individual was quite variable with up to 19 cycles difference between the sample types. CONCLUSION: We found that saliva is an equivalent sample type to nasopharyngeal swab for the detection of SARS-CoV-2 in our laboratories using multiple assay combinations and is suitable for use as a diagnostic and surveillance test for selected groups of individuals.


Subject(s)
COVID-19 , Nucleic Acids , COVID-19/diagnosis , Clinical Laboratory Techniques/methods , Humans , Nasopharynx , New Zealand , SARS-CoV-2/genetics , Saliva , Specimen Handling/methods
2.
Bioconjug Chem ; 32(8): 1606-1616, 2021 08 18.
Article in English | MEDLINE | ID: covidwho-1284671

ABSTRACT

In the near future, the increase in the number of required tests for COVID-19 antibodies is expected to be many hundreds of millions. Obviously, this will be done using a variety of analytical methods and using different antigens, including peptides. In this work, we compare three method variations for detecting specific immunoglobulins directed against peptides of approximately 15-aa of the SARS-CoV-2 spike protein. These linear peptide epitopes were selected using antigenicity algorithms, and were synthesized with an additional terminal cysteine residue for their bioconjugation. In two of the methods, constructs were prepared where the peptide (F, function) is attached to a negatively charged hydrophilic spacer (S) linked to a dioleoylphosphatidyl ethanolamine residue (L, lipid) to create a function-spacer-lipid construct (FSL). These FSLs were easily and controllably incorporated into erythrocytes for serologic testing or in a lipid bilayer deposited on a polystyrene microplate for use in an enzyme immunoassays (EIA). The third method, also an EIA, used polyacrylamide conjugated peptides (peptide-PAA) prepared by controlled condensation of the cysteine residue of the peptide with the maleimide-derived PAA polymer which were immobilized on polystyrene microplates by physisorption of the polymer. In this work, we describe the synthesis of the PAA and FSL peptide bioconjugates, design of test systems, and comparison of the bioassays results, and discuss potential reasons for higher performance of the FSL conjugates, particularly in the erythrocyte-based serologic assay.


Subject(s)
Antibodies, Viral/analysis , Drug Design , Peptides/chemistry , Peptides/immunology , SARS-CoV-2/immunology , Antibodies, Viral/immunology , Spike Glycoprotein, Coronavirus/immunology
3.
Transfusion ; 61(4): 1171-1180, 2021 04.
Article in English | MEDLINE | ID: covidwho-1085273

ABSTRACT

BACKGROUND: The Coronavirus disease 2019 (COVID-19) pandemic is having a major global impact, and the resultant response in the development of new diagnostics is unprecedented. The detection of antibodies against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has a role in managing the pandemic. We evaluated the feasibility of using SARS-CoV-2 peptide Kode Technology-modified red cells (C19-kodecytes) to develop an assay compatible with existing routine serologic platforms. STUDY DESIGN AND METHODS: A panel of eight unique red cells modified using Kode Technology function-spacer-lipid constructs and bearing short SARS-CoV-2 peptides was developed (C19-kodecyte assay). Kodecytes were tested against undiluted expected antibody-negative and -positive plasma samples in manual tube and three column agglutination technology (CAT) platforms. Parallel analysis with the same peptides in solid phase by enzyme immunoassays was performed. Evaluation samples included >120 expected negative blood donor samples and >140 COVID-19 convalescent plasma samples, with independent serologic analysis from two centers. RESULTS: Specificity (negative reaction rate against expected negative samples) in three different CAT platforms against novel C19-kodecytes was >91%, which correlated with published literature. Sensitivity (positive reaction rate against expected positive convalescent, PCR-confirmed samples) ranged from 82% to 97% compared to 77% with the Abbott Architect SARS-CoV-2 IgG assay. Manual tube serology was less sensitive than CAT. Enzyme immunoassay results with some Kode Technology constructs also had high sensitivity. CONCLUSIONS: C19-kodecytes are viable for use as serologic reagent red cells for the detection of SARS-CoV-2 antibody with routine blood antibody screening equipment.


Subject(s)
Antibodies, Viral/blood , COVID-19 Serological Testing , COVID-19 , Erythrocytes/metabolism , SARS-CoV-2/metabolism , COVID-19/blood , COVID-19/diagnosis , Humans
4.
J Virol Methods ; 289: 114042, 2021 03.
Article in English | MEDLINE | ID: covidwho-988684

ABSTRACT

Utilising diverse molecular platforms has formed a solid foundation in New Zealand's COVID-19 response. We evaluated multiple extraction and PCR assays for the detection of SARS-CoV-2. We included 65 positive samples which were run on the Panther Fusion using a laboratory developed test (LDT, E gene target). Where viral RNA was extracted by MagNA Pure (MP) 96 extraction platform or EpMotion 5075/Geneaid extraction kit, SARS-CoV-2 detection was performed on Light Cycler (LC) 480 using a LDT (E gene) or 3 commercial assays; Certest Viasure (Orf1ab, N genes) GenePro (E, RdRp genes) and A* Star Fortitude (proprietary target). Median Cts on LC 480 LDT for specimens (n = 9) extracted on MP 96 (26.6) were lower than on EpMotion (31.6) whereas median Cts for specimens (n = 10) extracted on the Panther Fusion LDT (23.1) were comparable with MP 96 /LC480 LDT (23.6). Specimens tested on Panther Fusion LDT (n = 28), extracted by MP 96, and amplified using commercial assays showed good concordance with a few exceptions; lower median Ct values were seen for 2 targets on GenePro (16.9, 21.5) and Viasure (19.5, 21.1) than for the Panther Fusion LDT (24.2) and A* Star Fortitude (25.6). Specimens tested on MP 96 (n = 18) had comparable results using commercial assays, with lower median Cts for Viasure (22.2, 23.7) compared with the LC 480 LDT (24.7), GenePro (24.7,25.7) and A*Fortitude (25.1) assays. The study provides an early assessment of the performance characteristics of 3 extraction methods for viral RNA and 5 PCR assays for the detection of SARS-CoV-2.


Subject(s)
COVID-19 Testing/methods , COVID-19/diagnosis , Polymerase Chain Reaction/methods , RNA, Viral/analysis , SARS-CoV-2/isolation & purification , Disease Outbreaks , Humans , New Zealand/epidemiology , Sensitivity and Specificity , Specimen Handling
SELECTION OF CITATIONS
SEARCH DETAIL